Skip to content
CutronexAutomation Reference

What is ISO 13849-1 Performance Levels (PL a–e)?

ISO 13849-1 specifies safety requirements and design principles for safety-related parts of machinery control systems (SRP/CS), classifying risk reduction capability into five discrete Performance Levels from PL a (lowest) to PL e (highest) based on Category architecture, MTTFD, Diagnostic Coverage, and Common Cause Failure.

What are the key specifications?

ParameterSpecification
Governing StandardISO 13849-1:2023 (Safety of machinery — Safety-related parts of control systems)
Performance LevelsPL a, PL b, PL c, PL d (PFHD < 10^-6/h), PL e (PFHD < 10^-7/h)
Architectures (Categories)Cat B, Cat 1 (well-tried), Cat 2 (test channel), Cat 3 & Cat 4 (dual-channel)
Key Reliability MetricsMTTFD (mean time to dangerous failure), DCavg (diagnostic coverage), CCF (>= 65 pts)
Validation ToolingSISTEMA (IFA) commonly used to compute subsystem PL

Sources and scope

ISO 13849-1:2023 Safety of machinery — Safety-related parts of control systems — Part 1: General principles for design.

Record date:

Suggest a correction

Where is it used?

  • Sizing emergency stop, safety light curtain, and interlock guard door circuits on automated machines.
  • Selecting dual-channel safety relays, safety PLCs, and Safe Torque Off (STO) variable frequency drives.
  • Substantiating CE Machinery Directive/Regulation risk reduction documentation.

What are the common pitfalls?

  • Claiming PL e using a single-channel mechanical contactor without redundant dual-channel architecture and mirror-contact monitoring (EDM).
  • Ignoring B10D mechanical cycle limits on electro-mechanical safety relays and pneumatic dump valves operating at high cycle rates.
  • Running dual-channel OSSD safety signals through the same unshielded cable without fault exclusion or cross-circuit detection.