What is IK08 / IK10 Impact Protection (IEC 62262)?
IEC 62262 (IK code) classifies the degree of protection provided by electrical enclosures against external mechanical impacts, where IK08 certifies 5 joules and IK10 certifies the maximum standard rating of 20 joules.
What are the key specifications?
| Parameter | Specification |
|---|---|
| Governing Standard | IEC 62262 (replacing EN 50102) |
| IK08 Impact Energy | 5 Joules (1.7 kg striker dropped from 300 mm) |
| IK09 Impact Energy | 10 Joules (5.0 kg striker dropped from 200 mm) |
| IK10 Impact Energy | 20 Joules (5.0 kg steel striker dropped from 400 mm) |
| Pass Criteria | Must maintain declared IP rating and dielectric/safety integrity post-impact |
Sources and scope
IEC 62262 Ed. 1.0 Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code).
Record date:
Where is it used?
- Factory-floor HMI touchscreens, machine vision cameras, and emergency-stop pendant stations.
- Heavy-duty rectangular connectors and polycarbonate field junction boxes along forklift aisles.
- Public infrastructure, logistics sorting, and mining surface control enclosures.
What are the common pitfalls?
- Assuming metal enclosures automatically achieve IK10; thin sheet-metal doors or viewing windows often fail at < 5 J.
- Overlooking cold-temperature embrittlement when specifying polycarbonate housings rated IK10 at +23 °C.