What is IP67 (IEC 60529)?
IP67 under IEC 60529 certifies dust-tight protection and survival under temporary water immersion (1 meter depth measured to the lowest point of the enclosure for 30 minutes).
- Temporary immersion is the relevant water test.
- Verify water-jet protection separately when the installation requires it.
What are the key specifications?
See the source publications and editions
| Parameter | Specification |
|---|---|
| Governing Standard | IEC 60529 |
| First Digit (6) | Dust-tight (complete exclusion of dust) |
| Second Digit (7) | Temporary immersion: 1 m depth (bottom) / >= 150 mm (top) for 30 min |
| Water Pressure Equiv. | ~10 kPa static head |
| Typical Hardware | On-machine IO-Link I/O blocks, proximity sensors, M8/M12 cordsets |
Sources and scope
IEC 60529 Ed. 2.2 Clause 14.2.7.
Record date:
Where is it used?
- Cabinet-free distributed fieldbus I/O blocks bolted directly onto machine frames.
- CNC coolant-flooded inductive proximity sensors and limit switches.
- M8 and M12 field-attachable and overmolded sensor/actuator cordsets.
What are the common pitfalls?
- Assuming IP67 covers high-pressure hot washdown jets; IP67 does NOT automatically include IP65/IP66 or IP69K.
- Leaving unused ports on an IP67 I/O block uncapped instead of sealing with M12 blind plugs.
- Thermal shock when warm enclosures are submerged in cold water creates internal vacuum that draws moisture past seals.