What is IP67 (IEC 60529)?

IP67 under IEC 60529 certifies dust-tight protection and survival under temporary water immersion (1 meter depth measured to the lowest point of the enclosure for 30 minutes).

  • Temporary immersion is the relevant water test.
  • Verify water-jet protection separately when the installation requires it.

What are the key specifications?

See the source publications and editions

ParameterSpecification
Governing StandardIEC 60529
First Digit (6)Dust-tight (complete exclusion of dust)
Second Digit (7)Temporary immersion: 1 m depth (bottom) / >= 150 mm (top) for 30 min
Water Pressure Equiv.~10 kPa static head
Typical HardwareOn-machine IO-Link I/O blocks, proximity sensors, M8/M12 cordsets

Sources and scope

IEC 60529 Ed. 2.2 Clause 14.2.7.

Record date:

Suggest a correction

Where is it used?

  • Cabinet-free distributed fieldbus I/O blocks bolted directly onto machine frames.
  • CNC coolant-flooded inductive proximity sensors and limit switches.
  • M8 and M12 field-attachable and overmolded sensor/actuator cordsets.

What are the common pitfalls?

  • Assuming IP67 covers high-pressure hot washdown jets; IP67 does NOT automatically include IP65/IP66 or IP69K.
  • Leaving unused ports on an IP67 I/O block uncapped instead of sealing with M12 blind plugs.
  • Thermal shock when warm enclosures are submerged in cold water creates internal vacuum that draws moisture past seals.