Skip to content
CutronexAutomation Reference

What is PROFINET (IEC 61158 / IEC 61784)?

PROFINET is an open Industrial Ethernet standard defined under IEC 61158 and IEC 61784 supporting standard TCP/IP diagnostics alongside deterministic cyclic Real-Time (RT) and clock-synchronized Isochronous Real-Time (IRT) automation I/O.

What are the key specifications?

ParameterSpecification
Governing StandardsIEC 61158 Type 10 / IEC 61784-1 & IEC 61784-2
Physical Layer100BASE-TX (100 Mbps Full Duplex) or fiber optic
Performance ClassesRT (cycle times >= 1 ms) and IRT (cycle times < 1 ms, jitter < 1 us)
Max Copper Segment100 m between active Ethernet ports (switches/devices)
Device DescriptionGSDML (General Station Description Markup Language XML)
Industrial ConnectorsRJ45 (IP20) or M12 D-coded / X-coded (IP65/IP67)

Sources and scope

PI (PROFIBUS & PROFINET International) Technical Specification and IEC 61158/61784.

Record date:

Suggest a correction

Where is it used?

  • High-speed discrete factory automation connecting PLCs to remote I/O blocks and pneumatic valve islands.
  • Synchronized multi-axis servo motion control using PROFINET IRT and PROFIdrive profiles.
  • Combined standard and functional safety machine networks utilizing PROFIsafe over PROFINET.

What are the common pitfalls?

  • Assigning an IP address without setting the exact PROFINET Device Name; PROFINET IO discovery relies on Name of Station.
  • Inserting unmanaged office switches that strip VLAN Priority 6 tags (IEEE 802.1Q) or disrupt LLDP topology detection.
  • Mixing non-IRT switches inside an IRT sync domain, causing deterministic cycle faults.