What is CANopen (EN 50325-4 / CiA 301)?
CANopen is a higher-layer communication protocol and device-profile framework built on ISO 11898 CAN bus, standardized under EN 50325-4 and CiA 301 for embedded machine control, mobile equipment, and drives.
What are the key specifications?
| Parameter | Specification |
|---|---|
| Governing Standards | EN 50325-4 / CiA 301 (Application Layer) & ISO 11898-2 (PHY) |
| Data Rates | 10 kbps up to 1 Mbps (8 standard CiA bit rates) |
| Max Bus Length | 25 m @ 1 Mbps; 100 m @ 500 kbps; 500 m @ 125 kbps; 1,000 m @ 50 kbps |
| Node Addressing | Node IDs 1–127 (7-bit address space) |
| Communication Objects | PDO (cyclic real-time), SDO (configuration), NMT, SYNC, EMCY |
| Termination | 120 ohm differential resistor at both trunk ends |
Sources and scope
CAN in Automation (CiA) 301 v4.2.0 and EN 50325-4.
Record date:
Where is it used?
- Internal sub-machine networking inside packaging machinery, medical devices, and off-highway vehicles.
- Servo and stepper drive coordination using CiA 402 drive device profiles.
- Hydraulic proportional valve controllers, inclinometers, and rotary encoders.
What are the common pitfalls?
- Connecting nodes configured for mismatched baud rates immediately triggers CAN bus-off error frames.
- Assigning duplicate Node IDs on the trunk causes arbitration collisions in SDO/PDO traffic.
- Using ordinary unshielded multi-conductor cable instead of 120-ohm nominal impedance twisted pair.